GEOSIP // REV 2 TECHNICAL BRIEF · NC RESIDENTIAL WALL SYSTEM
Preliminary Concept · Not For Construction Estimates & Projections Only
CEMENT-FREE GEOPOLYMER STRUCTURAL INSULATED WALLS // REV 2

GeoSIP
Wall System

A monolithic, stone-like structural insulated wall system built directly on site: one person hand-stacks lightweight interlocking EPS foam blocks (~22.5 lb each) with zero cranes or heavy lifting gear, then sprays fiber-reinforced, cement-free geopolymer skins on both faces. Engineered for fast, effortless site erection, lower projected lifetime cost, continuous thermal comfort, and solid masonry permanence.

ON-SITE HAND-STACKED EPS BLOCKS (~22.5 LB) · SPRAYED GEOPOLYMER SKINS · ZERO CRANES · ZERO DRYWALL · ZERO SIDING
Concept architectural render of a modern compact GeoSIP residence with smooth integral-colored monolithic mineral walls and clean vertical reveal joints
FIG 01 · Concept Render — Monolithic Mineral Wall Envelope CONCEPT ILLUSTRATION
Engineering Disclosure
Every cost, weight, schedule, R-value, and structural value on this page is a preliminary Rev 2 engineering estimate derived from modeled assemblies. GeoSIP is not yet code-listed or lab-certified; physical mock-up testing and a per-house North Carolina PE stamp (2018 NCRC R104.11) are required prior to construction.
Est. 30-Yr TCO Savings vs Wood 2×6
-$3,564 to -$8,962
On-site spray (owned rig): -$3,564 (One 600 ADU) to -$8,962 (1,800 sf house). House #1 rented gear beats wood direct. Modeled estimates.
Est. On-Site Dry-In Duration
4.5–6.5 d
One-person foam stack + site-spray shell vs 13.0–20.0 site days for Wood 2×6 framing, sheathing, siding, insulation & drywall.
Modeled Continuous Core Insulation
R-22
Projected effective value from unbroken 6.0-in EPS core with zero wood or steel thermal bridges (targets NC CZ4 R-20 code).
Projected Structural Wind Target
120 mph
Exposure C design target (L/500+ to L/581 modeled deflection) with 1.0-in interior concrete thermal barrier (NCRC R316.5.1 target).

* All KPI values above are modeled Rev 2 projections reconciled to identical exterior-wall scopes (structure, insulation, WRB/seals, exterior & interior finish, erection, waste, and 8% contingency; excluding shared slab, roof, windows, doors, and MEP rough-in). House #1 site-spray on rented gear ($0 capex) projects -$112 Direct (One 600) to -$1,002 Direct (1,800 sf) vs Wood; larger savings assume an owned $22,090 mobile rig amortized across 50 houses/yr.

One Monolithic Assembly Replacing Five Conventional Wall Trades

Conventional stick-built exterior walls stack framing, OSB sheathing, housewrap, cavity batt insulation, vinyl siding, and taped/painted gypsum drywall across separate trades. GeoSIP consolidates structural shell, continuous insulation, thermal barrier, and finished architectural surfaces into a single mineral-and-EPS composite wall.

01 · Cost & 30-Yr TCO

Projected Below Wood 2×6

Eliminating siding, drywall, framing lumber, and multi-trade markups projects Owner-Bid savings of -$136 to -$2,952 on a 600 sf ADU and -$1,937 to -$6,077 on a 1,800 sf house vs Wood 2×6, with lower modeled maintenance and HVAC carry over 30 years.

Modeled Estimate

02 · Effortless Site Placement

4.5 to 6.5 Projected Site Days

One worker easily hand-carries and stacks full-height ~22.5 lb interlocking foam blocks right onto the slab—no cranes, no heavy lifts, no precast factory wait. On-site sprayed mineral skins finish the shell in 4.5 to 6.5 projected site days, replacing an estimated 13 to 20 site days (101–186 MH) of wood framing, sheathing, siding, and drywall.

Zero Cranes · Zero Shop

03 · Fire Resistance

1.0-in Interior Mineral Barrier

Designed to meet 2018 NCRC / IRC R316.5.1 using a full 1.0-in interior geopolymer concrete skin over foam plastic—targeting zero drywall and avoiding multi-month NFPA 286 listing delays for Houses 1–3. Noncombustibility (ASTM E136) pending lab test.

ASTM E136 Pending

04 · Thermal Envelope

Continuous R-22 Core

An unbroken 6.0-in ASTM C578 EPS core paired with non-metallic 45° GFRP shear ties eliminates both wood-stud and steel-truss thermal bridging, projecting R-22 effective insulation designed to exceed North Carolina Climate Zone 4 R-20 wall requirements.

Modeled R-Value

05 · Durability

Rot, Mold & Termite Resistant

Inorganic geopolymer mineral skins, closed-cell EPS foam, AR-glass mesh, and GFRP reinforcement contain zero wood studs, zero paper-faced drywall, and zero rust-prone steel shear trusses—designed for humid Southeast climates with breathable matte siloxane exterior sealing.

Inorganic Assembly

06 · Wind & Structure

120 mph Exp C Target

Composite sandwich action via continuous 45° AR-glass/epoxy GFRP shear-grid strips (@ 24 in o.c.) plus a cast haunched 3-in bond beam and embedded Simpson HETA20 truss anchors targets L/500+ to L/581 deflection and P_cr = 10,750 plf (symmetric baseline).

AC422 & PE Pending

07 · Architectural Finish

Integral-Color Mineral Walls

Pigmented throughout with mineral iron-oxide color for a smooth, matte stone-like finish inside and out—zero vinyl siding to fade and zero drywall seams to mud. An optional limestone elastomeric formliner facade is priced as a future post-House-3 upgrade (+$1,547 / +$2,522 Direct est.).

Smooth Baseline

08 · Local Supply & Carbon

Proprietary Cement-Free Mix

Our ambient-cured mineral geopolymer formulation uses abundant regional industrial byproducts and local North Carolina & Southeast aggregates—replacing Ordinary Portland Cement with zero heat-curing kilns required. Specific mix ratios and suppliers remain proprietary.

Cylinder Tests Pending

7.75-in / 8.0-in Composite Wall Anatomy

Orthographic engineering cross-section of the GeoSIP wall: Plan View showing flat 45-degree GFRP shear grid sandwiched in the vertical seam between two 6.0-in EPS blocks bridging exterior and interior skins, and Vertical Section showing 3.0-in cast bond beam with 2 #4 GFRP bars, HETA20 anchor, AR-glass mesh, and slab U-channel sill track
FIG 02 · Wall Cross-Section Cutaway (0.75" Ext / 6.0" EPS / 1.0" Int) SCHEMATIC DIAGRAM
Wall Layer / Component Rev 2 Specification Design Role
Exterior Mineral Skin 0.75 in (rec.)
1.00 in (base)
Fiber-reinforced geopolymer (0.5% AR-glass fiber + 4.5 oz AR mesh), integral iron-oxide color, matte breathable siloxane sealer.
Insulating Core 6.00 in EPS 1.25 pcf nominal ASTM C578 Type I/II rigid EPS foam; CNC-cut tie kerfs, bond-beam trough, lintel troughs, and interior wire chases. Modeled R-22 effective.
Interior Mineral Skin 1.00 in Kept at full 1.0 in across all variants to target 2018 NCRC / IRC R316.5.1 concrete thermal barrier over foam plastic (no drywall).
Composite Shear Ties 45° GFRP
@ 24" o.c.
Continuous AR-glass/epoxy GFRP shear-grid strips (AC422 type); zero metallic thermal bridge; modeled K_sh = 418 psi (1.0/1.0) / ~360 psi (0.75/1.0).
Top Bond Beam & Uplift 3.0 in cast
2 #4 GFRP
Monolithic haunched geopolymer bond beam (1.5-in fillets, AR mesh, 2 #4 GFRP bars) with embedded Simpson HETA20 roof truss anchors.
Openings & Lintels 10.0 in cast
2 #4 GFRP
Monolithic cast geopolymer lintels over windows and 6'-2" patio sliders; eliminates steel C-channel (saving -$1,263 Direct est. on One 600).
Electrical Chases 1.5" × 1.5" Hot-wire routed interior EPS chases + clean baseboard/surface raceway; field-wired by a licensed NC electrician so NC Modular rules do not apply.

Modeled composite stiffness (corrected Newmark check, EA* = EA/2): symmetric 1.0/1.0 baseline models I_c = 296.0 in⁴/ft, K_sh = 418 psi at γ = 0.020, L/581 deflection, P_cr = 10,750 plf; recommended 0.75/1.0 models I_c = 247 in⁴/ft, L/500+ at 120 mph Exp C. All structural numbers await AC422 push-off prisms and NC PE review.

How the 45° GFRP Shear Grid Installs
The 45° GFRP grid is a prefabricated flat truss strip (~1/8" thick × 7.25" wide × 9'-0" tall, e.g., C-GRID®/AC422 class)—never threaded diagonally through solid foam. Strips slide straight into CNC-cut vertical through-kerfs at 24" o.c. (or sandwich directly between 2'-0" interlocking foam sub-blocks). Outer truss chords protrude ~0.5" past both foam faces so the sprayed geopolymer skins encapsulate them monolithically.
Property / Load Case GeoSIP Rev 2 Target Wood 2×6 + Drywall Practical Meaning & Code Basis
Compressive StrengthGeopolymer mineral skin ≥ 3,000 psi (24h)
≥ 5,000 psi (28d)
Gypsum ~300–500 psi Stronger than typical 3,000–4,000 psi residential slab concrete; cylinder tests pending before House #1.
Surface Hardness & ImpactScratch, dent & hail Mohs ~5–6Stone-like mineral Mohs ~2 (drywall)Vinyl dents/cracks Comparable to architectural concrete or travertine—resists furniture bumps, kids, hail, and impact without hollow drywall holes.
Flexural Strength (f_r)Fiber + AR-mesh skin ~530–700 psi Brittle paper face 0.5% AR-glass micro-fibers + 4.5 oz AR-glass mesh control shrinkage cracks and carry wind suction across 24"–36" tie spacing.
Axial Gravity Load (P_cr)Vertical roof/wall load 8,000–10,750 plfModeled buckling ~2,500–3,500 plf Massive structural reserve vs typical ~1,200 plf 1-story residential roof load (pending AC422 push-off & NC PE calc).
Wind & Roof Uplift120 mph Exp C target L/500+ to L/581HETA20 ~2,000+ lb L/240–L/360 code Continuous 3.0-in haunched bond beam with 2 #4 GFRP bars and embedded Simpson HETA20 hurricane straps tie roof directly to mineral shell.
Interior Hanging Loads1.0-in solid mineral face 30–75 lb (anchors)
150–300+ lb (blocked)
Stud-only heavy loads Art hangs with adhesive/masonry pins; shelves & mirrors use 3/16" Tapcons into the 1.0-in skin; TVs & cabinets use pre-spray blocking.
Acoustic InsulationSound transmission STC ~46–52Modeled mass-spring STC ~34–38 Two dense mineral skins decoupled by 6.0-in EPS damp street traffic, rain, and wind for a noticeably quieter, vault-solid interior.
Shrinkage & Cure HeatDimensional stability < 0.07% (C157)
< 70°C exotherm
Seasonal wood swell Ambient-cured geopolymer stays safely below EPS softening temp and avoids wood stud warping or drywall nail pops.
PROPRIETARY FORMULATION // REDACTED
Materials List & Mix Ratios Held Private

Our cement-free geopolymer chemistry, activator ratios, spray rheology package, and regional North Carolina supply chain are proprietary to GeoSIP. Full itemized BOMs are shared under NDA with engineering and build partners.

Stack Featherweight Foam by Hand. Spray Solid Stone on Site.

GeoSIP is built directly on the slab using on-site spray over hand-stacked foam blocks: minimal equipment, effortless one-person placement even on tight backyard ADU lots, zero vertical panel joints, and lowest projected cost from House #1.

Technical build schematic showing 3-step on-site spray-on foam block sequence: hand-stacking 4x9 EPS blocks into a slab U-channel sill track, sliding in 45-degree GFRP shear grids with top alignment track and slim telescoping push-pull struts, and spraying monolithic geopolymer skins
FIG 03 · 3-Step On-Site Spray Process — Stack Blocks, Lock Alignment Rail & GFRP Grid, Spray Mineral Skins PROCESS SCHEMATIC

Step 01 · Hand-Stack Foam

~22.5 lb Interlocking Blocks

One worker snaps full-height 4'-0" × 9'-0" × 6.0-in CNC ship-lap EPS blocks straight into a continuous aluminum U-channel sill track anchored to the slab (25 blocks One 600 / 45 blocks 1,800 sf). Zero cranes, zero heavy lifts, and works on any tight residential lot.

Step 02 · Grid & Laser-Plumb Rail

Clean Track & Telescoping Struts

Flat 45° GFRP shear-grid strips slide into factory vertical kerfs (24" o.c.) and AR-glass mesh clips onto standoffs. A reusable continuous top alignment track paired with slim quick-release telescoping push-pull struts holds the entire wall run dead-plumb without bulky rigging.

Step 03 · Spray Monolithic Stone

4.5–6.5 Projected Site Days

A 3–4 person crew sprays fiber-reinforced geopolymer onto both faces in 2 rapid passes (0.75" ext / 1.0" int), encapsulating the GFRP grid into one seamless, joint-free shell—$0 capex on House #1 with rented gear, or $22,090 owned mobile rig at scale.

Apples-to-Apples Exterior Wall Comparison vs Wood, Steel & OSB SIP

All systems are modeled on identical exterior-wall scopes (structure, insulation, WRB/seals, exterior & interior finish, erection, waste, and 8% contingency; excluding shared slab, roof, windows, doors, and MEP rough-in). Owner-Bid applies Direct × 1.10 shop × 1.15 GC (1.265×) for GeoSIP vs Raleigh subcontract rates + 15% GC. 30-yr TCO (7% discount rate) includes wall HVAC NPV, maintenance NPV, per-house NC PE stamp ($2,000 One 600 / $2,500 1,800 sf), and schedule carry credit vs Wood.

Table A · One 600 ADU (738 sf Net Wall · 98 lf Perimeter) — Modeled Estimates

Wall System Direct Est. Owner-Bid Est. 30-Yr TCO Est. Site Time
GeoSIP On-Site SprayOwned mobile rig ($22k) · Seamless monolithic $8,249-$1,367 vs Wood $10,435-$2,952 vs Wood $12,036-$3,564 vs Wood 4.5 days58 MH
GeoSIP On-Site Spray (House #1)$0 equip capex · Rented pump & braces $9,504-$112 vs Wood $12,023-$1,364 vs Wood $13,624-$1,976 vs Wood 4.5 days58 MH
Wood 2×6 BaselineStick-built · Vinyl siding + drywall $9,616Baseline $13,387Baseline $15,600Baseline 13.0 days101 MH
CFS Steel StudCI + vinyl siding + drywall $12,038+$2,422 vs Wood $16,661+$3,274 vs Wood $19,003+$3,403 vs Wood 14.0 days117 MH
OSB SIP 6.5-inVinyl siding + drywall $14,150+$4,534 vs Wood $18,237+$4,850 vs Wood $19,236+$3,636 vs Wood 8.0 days86 MH

Table B · 1,800 sf Residence (1,348 sf Net Wall · 180 lf Perimeter) — Modeled Estimates

Wall System Direct Est. Owner-Bid Est. 30-Yr TCO Est. Site Time
GeoSIP On-Site SprayOwned mobile rig ($22k) · Seamless monolithic $14,574-$3,039 vs Wood $18,436-$6,077 vs Wood $19,593-$8,962 vs Wood 6.5 days100 MH
GeoSIP On-Site Spray (House #1)$0 equip capex · Rented pump & braces $16,611-$1,002 vs Wood $21,013-$3,500 vs Wood $22,170-$6,385 vs Wood 6.5 days100 MH
Wood 2×6 BaselineStick-built · Vinyl siding + drywall $17,613Baseline $24,513Baseline $28,555Baseline 20.0 days186 MH
CFS Steel StudCI + vinyl siding + drywall $21,988+$4,375 vs Wood $30,432+$5,919 vs Wood $34,710+$6,155 vs Wood 22.0 days214 MH
OSB SIP 6.5-inVinyl siding + drywall $25,846+$8,233 vs Wood $33,312+$8,799 vs Wood $34,761+$6,206 vs Wood 12.0 days153 MH

* All totals are modeled Rev 2 estimates on identical exterior-wall scopes. House #1 on rented gear ($0 capex) projects -$112 Direct (One 600) to -$1,002 Direct (1,800 sf) vs Wood; larger savings assume the owned $22,090 mobile rig amortized across volume and remain estimates until the $500 4×8 mock-up confirms field spray labor and rebound.

The Feel of Solid European Stone. Built in Days.

Most American homes are hollow stick-and-drywall boxes that transmit street noise, dent from a chair bump, harbor moisture and termites, and need repainting and siding replacement. Living inside a monolithic mineral GeoSIP home feels fundamentally different—calm, solid, whisper-quiet, and built for generations.

Concept architectural exterior view of a single-story GeoSIP home with smooth integral-colored monolithic geopolymer walls, flush modern windows, and clean architectural reveal joints
FIG 04 · Exterior Concept — Monolithic Stone-Like Mineral Facade CONCEPT RENDER · NOT BUILT
Concept minimalist residential interior featuring smooth integral-colored geopolymer mineral walls, clean vertical reveal joints, recessed baseboard raceway, and soft natural daylight
FIG 05 · Interior Concept — Smooth Mineral Finish & Calm Acoustic Mass CONCEPT RENDER · NOT BUILT

Quiet, Solid Masonry Feel

Zero Hollow-Wall Echo

Tap a GeoSIP wall and it feels like carved stone, not paper-faced drywall over empty stud bays. Dense mineral skins paired with 6 inches of continuous foam damp outside traffic, wind, and rain—creating a serene, vault-solid interior with steady, draft-free thermal comfort all year.

Generational Durability

Fire, Pest, Rot & Mold Immune

Because the shell is 100% inorganic stone-like mineral and closed-cell EPS—with zero wood studs, zero paper drywall, and zero vinyl siding—it will not rot, host mold, feed termites, or fade in UV. Pigmented through the body, the matte architectural finish ages like natural masonry.

Everyday Living & Easy Care

Solid 1.0-in Interior Skin

Seamless site-sprayed walls eliminate drywall tape cracks. Light art hangs with adhesive strips or masonry nails; heavy shelves anchor cleanly into the 1.0-in mineral skin (with shop/pre-spray blocking for TVs and cabinets). Any chip patches flush with matching mineral compound and a quick sand.

What Is Modeled vs. What Must Be Physically Tested

Zero Unverified Claims Policy
GeoSIP Rev 2 is a preliminary engineering concept. It does not hold an ICC-ES evaluation report, DrJ TER, Intertek CCRR, UL listing, or completed third-party lab certification. Houses 1–3 require a site-specific North Carolina Professional Engineer (PE) stamp under 2018 NCRC R104.11 / IRC R301.1.3 backed by the physical tests listed below.
Validation Gate Status Target Metric / Code Path Why Required Before House #1
1. Weekend 4'×8' Vertical Spray Mock-Up (~$500 est. + ~$200 bench screen) Required First Compare retarded two-part geopolymer vs one-part / slag-CSA mineral mortar; rebound <15%; 4 core drills proving zero mesh voids & ≥1.0-in interior (ACI 506.2). Verifies caustic mist safety, pump washout, vertical sag resistance, screed finish flatness, and actual spray labor before committing to site spraying.
2. Ambient Binder & Stalite Cylinders Not Yet Cast 24h ≥ 3,000 psi, 28d ≥ 5,000 psi, peak exotherm <70°C against EPS, ASTM C157 shrinkage <0.07%; Stalite 108 pcf equilibrium density check. Confirms ambient slag/fly-ash cure without kilns and verifies actual Stalite geopolymer density & strength before stamping structural calcs.
3. AC422 Shear-Grid Push-Off & Pullout Not Yet Tested Composite stiffness K_sh ≥ 418 psi (1.0") / ≥360 psi (0.75"), tie pullout ≥1,200 lb. Validates Newmark composite bending assumptions (L/500+ to L/581 at 120 mph Exp C) for NC PE review.
4. ASTM E136, Bond Beam, Lintel & Finish Checks Not Yet Tested ASTM E136 noncombustibility; 4'×8' haunched 3-in bond beam & 6'-2" lintel load test (L/240); HETA20 pullout; patch color match & seam cracking. Supports NCRC R316.5.1 concrete thermal-barrier compliance, roof uplift anchorage, and architectural durability under thermal cycling.
5. NC PE Stamp & Local Code Pre-Check Per-House Path 2018 NCRC R104.11 / IRC R301.1.3 PE-sealed design + Raleigh R316.5.1 pre-check + unwired-shell confirmation (zero NC Modular). Required permitting pathway for Houses 1–3 prior to funding any broader $65k–$90k ISO 17025 / DrJ TER / Intertek CCRR listing campaign.

STAGE 01: REV 2 BOM & SITE-SPRAY MODELS [COMPLETE] · STAGE 02: $500 MOCK-UP & CYLINDER/AC422 LAB MATRIX [NEXT] · STAGE 03: NC PE STAMP & HOUSE #1 PROTOTYPE [PENDING]